Bakelite Strip Connector
 
Open Type Connectors 15 AMPS
 
 Rating : 15 Amps.
 Housing : High Grade (PF) Moulding Powder
 Terminals : Brass Duly Nickle Plated
 Screws : Steel Zinc plated, Yellow chromated
 Washer : Steel Zinc plated, Yellow chromated
 Insulation resistance : >20MW (Min) at 500V.DC
 H.V.Test : 2.5 KV Test Between Two Adjacent Terminals For 1 Min.
 Wire Size : 2.5 Sq. mm. (Max.)
 No.Of Way : 2 Ways To 12 Ways
 
 
Open Type Connectors 30 AMPS
 
 Rating : 30 Amps.
 Housing : High Grade (PF) Moulding Powder
 Terminals : Brass Duly Nickle Plated
 Screws : Steel Zinc plated, Yellow chromated
 Washer : Steel Zinc plated, Yellow chromated
 Insulation resistance : >20MW (Min) at 500V.DC
 H.V.Test : 2.5 KV Test Between Two Adjacent Terminals For 1 Min.
 Wire Size : 4.0 Sq. mm. (Max.)
 No.Of Way : 2 Ways To 12 Ways
 
 
Open Type Connectors 60 AMPS
 
 Rating : 60 Amps.
 Housing : High Grade (PF) Moulding Powder
 Terminals : Brass Duly Nickle Plated
 Screws : Steel Nickle plated
 Washer : Steel Nickle plated
 Insulation resistance : >20MW (Min) at 500V.DC
 H.V.Test : 2.5 KV Test Between Two Adjacent Terminals For 1 Min.
 Wire Size : 16.0 Sq. mm. (Max.)
 No.Of Way : 2 Ways To 12 Ways
 
 
Close Type Connectors 5, 10, 15 & 30 AMPS
 
 Rating : 5 Amps / 10 Amps. / 15 Amps. / 30 Amps.
 Housing : High Grade (PF) Moulding Powder
 Terminals : Brass Duly Nickle Plated
 Screws : Steel Zinc plated
 Insulation resistance : >20MW (Min) at 500V.DC
 H.V.Test : 2.5 KV Test Between Two Adjacent Terminals For 1 Min.
 No.Of Way : 2 Ways To 12 Ways
 
 
Rigid Type Connectors 30 AMPS
 
 Rating : 30 Amps.
 Housing : High Grade (PF) Moulding Powder
 Terminals : Brass Duly Nickle Plated
 Screws : Steel Zinc plated
 Insulation resistance : >20MW (Min) at 500V.DC
 H.V.Test : 2.5 KV Test Between Two Adjacent Terminals For 1 Min.
 No.Of Way : 2 Ways To 6 Ways
 
 
Rigid Type Connectors 60 AMPS
 
 Rating : 60 Amps.
 Housing : High Grade (PF) Moulding Powder
 Terminals : Brass Duly Nickle Plated
 Screws : Steel Zinc plated
 Insulation resistance : >20MW (Min) at 500V.DC
 H.V.Test : 2.5 KV Test Between Two Adjacent Terminals For 1 Min
 No.Of Way : 2 Ways To 6 Ways
 
 
Add-On Type Terminal Block 30 AMPS & 100 AMPS With End Plate
 
 Rating : 30 Amps. / 100 Amps.
 Housing : High Grade (PF) Moulding Powder
 Terminals : Brass Duly Nickle Plated
 Screws : Steel Zinc plated
 Washer : Steel Zinc plated
 Insulation resistance : >20MW (Min) at 500V.DC
 H.V.Test : 2.5 KV Test Between Two Adjacent Terminals For 1 Min.
 
 
 
   
 
All Rights Reserved.